Intelect Transport 2 Combo is a two-channel electrotherapy, ultrasound therapy combo system providing Chattanooga product reliability and value. It’s lightweight and durable design with battery operation option provides the versatility to treat patients in the clinic or on the field. Its intuitive functionality provides ease of use and confidence in effective therapy.

  • Electrical Stim: 5 waveforms (Interferential, Premod, Russian, High Volt, VMS)
  • Dual Frequency Ultrasound: 1 MHz and 3.3 MHz frequencies with pulsed or continuous duty cycles (10%, 20%, 50%, and 100%). Comes standard with a 5cm2 ultrasound applicator

 Other Features of the Intelect Transport 2

  • Large Color LCD Screen: An easy to see high resolution screen provides real time information on the progress of the individual treatment.
  • Portability: Its lightweight and durable design coupled with an ergonomically designed handle make transporting the devise easy to treat patients whenever and wherever.
  • Optional Cart: Complete with large wheels and casters, magnetic fixation of the device to the cart for convenience and easy and secure attachment and detachment, and sufficient storage drawers make this optional cart a convenient and functional treatment, storage, and transport system. Dimensions: W-48cm, D-52cm, H-96cm, (108.5cm with device on cart). Weight: 22.27 lbs (10.1 kg)
  • Ultrasound: Improved coupling detection and monitoring for more effective and efficient treatments.
  • VMS Waveform:Chattanooga's proprietary VMS waveform achieves stronger muscle contractions and less neural fatigue while still providing a more comfortable experience for the patient. (
  • Improved Battery: Allows for reduced need for excess cables and provides all day use in portable settings.
  • Warranty: During the two-year warranty period from the date of delivery of the product to the end customer, defects will be remedied at no charge to the customer upon the customer furnishing adequate proof that the defect is due to defects in material or workmanship. The warranty period for accessories is 90 days. Accessories consist of Lead Wires and Electrodes. The warranty period for the Therapy System Cart and Ultrasound Applicators is one year (12 months).

Click HERE to view Intelect Transport 2 Combo Brochure

Click HERE to view Intelect Transport 2 Combo User’s Manual

Intelect Transport 2 Standard Accessories

SKU/Part Number

Description

4738

Intelect Transport 2 Combo

14679

Mains Power Cord

47335

Transport 2 Ultrasound Applicator 5cm2

48384

Transport 2 User Manual

40-0097

Leadwire Assy, Stim, CH1, STD

40-0098

Leadwire Assy, Stim, CH1, STD

42192

Dura-Stick Plus 5 cm (2”) Foam, Round Electrodes

 

Intelect Transport 2 Optional Accessories

SKU/Part Number

Description

70010

Stim CH1/2 Leadwire Kit STD (For Combo Device Only)

10648

Nylatex Wrap (2 per pack)

79967

6 x 8 cm (2.5 x 3 in) Carbon Electrodes (4 pk)

79970

Sponge Pocket 9 x 10.5cm (4 pk)

72852

3 in (8cm) Black Rubber Carbon Electrodes (2 pk)

72853

3 in (8cm) Red Rubber Electrodes (2 pk)

47334

Transport 2 Ultrasound Applicator 2cm2

47336

Transport 2 Ultrasound Applicator 10cm2

14-1086

Battery

15-1136

Cart

  

Indications for Use – Electrotherapy

  • Relaxation of muscle spasms
  • Prevention or retardation of disuse atrophy
  • Increasing local blood circulation
  • Muscle re-education
  • Maintaining or increasing range of motion
  • Symptomatic relief of chronic, intractable pain
  • Post-traumatic acute pain
  • Post-surgical acute pain

Indications for Use – Ultrasound

Relief of pain, muscle spasms, and joint contractures associated with a wide variety of musculoskeletal injuries and conditions.

  • “itis” conditions
  • Muscle spasms
  • Musculoskeletal syndromes/conditions
  • Muscle & ligament strains and sprains
  • Trigger points
  • Relief of sub-chronic and chronic pain and joint contractures resulting from capsular tightness and scaring

Technical Specifications:

Mains Power

100-240 VAC, 50/60 Hz, 1.0 A

Weight

4.9 lbs (2.2 kg)

Shipping Weight

8.5 lbs (3.9 kg)

Dimensions

13.6"L x 9.8"W x 4.7"H (34.6 cm x 25 cm x 12 cm)

Electrical Safety Class

Class 1, Electrotherapy Type BF, Ultrasound Type B

Safety Tests

IEC 60601-1, ISO 10993-1, IEC 60601-2-5, IEC 60601-1-2, IEC 60601-2-10, IEC 60601-1-6, IEC 62366-1, IEC 62304, IEC 62133, ISO 14971

 

SYSTEM SPECIFICATIONS

Power

  • Input: 100-240 VAC, 1.0 to 0.42 A, 50/60 Hz 100 W Max
  • Electrical Class: Class 1
  • Mode of Operation: Continuous

Output Power 

ULTRASOUND SPECIFICATIONS

Frequency

1 MHz; 3.3 MHz

Duty Cycles

10%, 20%, 50%, Continuous

Pulse Repetition Rate

100 Hz

Pulse duration

1 -5 ms

Max (ON): 5 ms

Min (OFF): 5ms

Peak to Average Ratio

1:1, at 50% Duty Cycle

4:1, at 20% Duty Cycle

9:1, at 10% Duty Cycle

Beam Nonuniformity Ratio

<5.1

Beam Type

Collimating

Treatment Time

1 to 30 minutes

 

WAVEFORMS

IFC (Interferential) Traditional (4 Pole)

Interferential Current is a medium frequency waveform. Current is distributed through two channels (four electrodes). The currents cross each other in the body at the area requiring treatment. The two currents interfere with each other at this crossing point, resulting modulation of the intensity (the current intensity increases and decreases at a regular frequency).

Output Mode

Electrodes

Available on Channels

1, 2

Treatment Time

1-60 Minutes

Mode Selection

CC or CV

Output Intensity

0-100 mA (CC)

Beat Frequency

1-200 Hz

Carrier Frequency

2000-10,000 Hz

Sweep Time

15 sec

Sweep Low Beat Frequency

1-199 Hz

Sweep High Beat Frequency

2-200 Hz

Scan Percentage

Static, 40%, 100%, Manual

IRMS

0-78mA

DC component

No

 

VMS

VMS is a symmetrical biphasic waveform with a 100 µsec interphase interval. Because the pulse is relatively short, the waveform has a low skin load, making it suitable for applications requiring high intensities, such as in muscle re-education protocols.

Output Mode

Electrodes

Available on Channels

1, 2

Treatment Time (Stim)

1-60 minutes

Treatment Time (Combo)

1-30 minutes

Mode Selection

CC or CV

Output Intensity

0-140 mA (CC) 0-140 V (CV)

 

 

Channel Mode

Single, Reciprocal, Co-Contract

Cycle Time

Continuous 5/5, 4/12, 10/10, 10/20, 10/30, 10/50

Frequency

1 – 200 pps

Phase Duration

20-400 μsec

Ramp

0.5 – 5 seconds

Set Intensity

Individual/both Channel Intensity, Setting in Reciprocal and Co-Contract Modes

IRMS

0-50mA

DC Component

No

  

IFC Premodulated (Traditional 2-Pole)

Premodulated Current is a medium frequency waveform. Current comes out of one channel (two electrodes). The current intensity is modulated: it increases and decreases

at a regular frequency (the Amplitude Modulation Frequency).

Output Mode

Electrodes

Available on Channels

1, 2

Treatment Time (Stim)

1-60 minutes

Treatment Time (Combo)

1-30 minutes

Mode Selection

CC or CV

Output Intensity

0-100 mA (CC) 0-100 V (CV)

Beat Fixed (Sweep Off)

1 – 200 Hz

Cycle Time

Continuous, 5/5, 4/12, 10/10, 10/20, 10/30, 10/50

Carrier Frequency

2,500 Hz

Sweep Low Beat Frequency

1 – 199Hz

Sweep High Beat Frequency

2 – 200Hz

IRMS

0-55mA

DC Component

No

 

Russian

Russian Current is a sinusoidal waveform, delivered in bursts or series of pulses. This method was claimed by its author (KOTA) to produce maximal muscle re-education effects without significant discomfort to patient.

Output Mode

Electrodes

Available on Channels

1, 2

Treatment Time

1-60 minutes

Mode Selection

CC or CV

Output Intensity

0-100 mA (CC) 0-100 V (CV)

Channel Mode

Single, Reciprocal, Co-Contract

Burst Frequency

20 – 100 bps

Carrier Frequency

2,500Hz

Cycle Time

Continuous, 5/5, 4/12, 10/10, 10/20, 10/30, 10/50

Duty Cycle

10%, 20%, 30%, 40%, 50%

Ramp

0.5 – 5 seconds

IRMS

0-39mA

DC Component

No

  

High Voltage Pulsed Current (HVPC)

The High Voltage Pulsed Current (HVPC) has a very brief pulse duration characterized by two distinct peaks delivered at high voltage. The waveform is monophasic (current flows in one direction only). The high voltage causes a decreased skin resistancemaking the current comfortable and easy to tolerate.

Output Mode

Electrodes

Available on Channels

1, 2

Treatment Time (Stim)

1-60 minutes

Treatment Time (Combo)

1-30 minutes

Mode Selection

CV

Output Intensity

0 – 500 V (CV)

Cycle Time

Continuous, 5/5, 4/12, 10/10, 10/20, 10/30, 10/50

Display

Volts or Peak Current

Frequency

10 – 120 pps

Polarity

Positive or Negative

Ramp

0.5 – 5 seconds

Sweep Frequency

Continuous, 80/120, 1/120, 1/10

IRMS

0-45mA

DC Component

0 – 1.5mA